Request a quote
Through-Conduit Slab Gate ValveIllustration
Gate valves

Through-Conduit Slab Gate Valve

Flat-plate (slab) gate valve with a through-conduit bore for pipeline service. In the open position the gate bore aligns with the pipe, allowing pigging and minimising pressure drop. Flanged or butt-weld ends.

PressureClass 150–900
SizesDN 25 to DN 1000 (1" to 40")
BodyASTM A216 WCB
EndsFlanged; butt-weld

Specifications

Specifications are for preliminary selection. Final configuration and ratings are subject to quotation and technical confirmation.

Design standard (on request)API 6D; ASME B16.34; GB/T 19672; JB/T 5298
Pressure classClass 150 to Class 900 (PN 1.6 to 15.0 MPa)
Size rangeDN 25 to DN 1000 (1" to 40")
Body materialASTM A216 WCB
Temperature-29 °C to 121 °C; other ranges on request
End connectionsFlanged; butt-weld

Dimensions and weights

1 Pressure class / table
2 Pick a size
NPS (in)DN (mm)L - flange (mm)L2 - light-duty (mm)H - hand-operated (mm)H2 - hand-operated (mm)H0 - hand-operated (mm)P - air/fluid (mm)P1 - air/fluid (mm)P0 - air/fluid (mm)H3 - non-diversion (mm)H1 - diversion (mm)
125127--360250180------6085
1 1/432140--375260180------71103
1 1/240165--410290250------75115
25017810845031525052543025085122
2 1/26519011255042030064856030091154
380203114610428300730630300109169
4100229127700494300850720300121193
61502671408956253501120920350178283
8200292152113078435014301160350211352
10250330165129093740016651380400215440
123003561781480108045019301550450245514
143503811901660128350021851750450280602
164004062161850141750024502000500310678
184504322222080148960027552250500346785
205004572292300167270030502450600363855
2460050826726802012800358029008004421045
2870061029230802250800413033508005051190
32800660318349125501000------5601350
36900711330389728501000------6101510
401000811460431732501200------7151715
4210501124--------------7851795
4411001219--------------8671894
4812001264--------------9932150
NPS (in)DN (mm)L - flange (mm)L1 - BW (mm)L2 - light-duty (mm)H - hand-operated (mm)H2 - hand-operated (mm)H0 - hand-operated (mm)P - air/fluid (mm)P1 - air/fluid (mm)P0 - air/fluid (mm)H3 - non-diversion (mm)H1 - diversion (mm)
125165165--370260180------7090
1 1/432178178--385270180------80115
1 1/240190190--420300250------85130
250216216--458325250533435200100137
2 1/265241241--555420300653565200106169
380282282--615430300735635200124184
4100305305150710500300860730250146218
61504034031509006253501125925350206311
8200419419180113579035014351165350241382
102504574571801401104040017761450400303476
123005025022001580115045020301620450372545
14350762762200------23051900500405645
16400838838218------25582100600450728
18450914914218------28352320700490800
20500991991229------31202510800520930
2460011431143248------367029808006001100
2870013461346286------------6651260
3280015241524286------------7201420
3690017271727--------------8201580
40100018801880--------------9501720
42105019811981--------------10701800
NPS (in)DN (mm)L - flange (mm)H - hand-operated (mm)H2 - hand-operated (mm)H0 - hand-operated (mm)P - air/fluid (mm)P1 - air/fluid (mm)P0 - air/fluid (mm)H3 - non-diversion (mm)H1 - diversion (mm)
250292468335300543445200108158
1 1/265330565430300663570200125190
380356625440350745640250145225
3100432720510350870740250165255
61505599106304001135930350220330
8200660114580050014451170350280410
102507871411105050017861460400330490
123008381590116060020401630450380570
14350889------------430650
16400991------------480735
184501092------------530810
205001194------------580905
225501295------------6401075
246001397------------7001160
266501448------------7601220
287001549------------8301330
307501651------------9001415
328001778--------------1540
369002083--------------1650
4010002150--------------1760
4210502300--------------1840
NPS (in)DN (mm)L - flange (mm)L1 - BW (mm)H - hand-operated (mm)H2 - hand-operated (mm)H0 - hand-operated (mm)P - air/fluid (mm)P1 - air/fluid (mm)P0 - air/fluid (mm)H3 - non-diversion (mm)H1 - diversion (mm)
250368368473335300548450250108158
1 1/265419419570435300668580300125190
380381381630445350750650350145225
4100457457725515350875745400165255
61506106109156404001140940500220330
8200737737115080050014501180550280410
102508388381416105550017911465600330490
123009659651595116560020451635700380570
1435010291029--------------690
1640011301130--------------800
1845012191219--------------890
2050013211321--------------985
2460015491549--------------1150

Dimensions in mm unless marked. Check against the drawing supplied with the quotation before final design.

For your quotation

Tell us these and we can quote. A short list or a datasheet is enough to start.

Need it actuated?This valve can be supplied with an electric actuator or a pneumatic cylinder. See our automated valves.
Size
Pressure class
Medium & temperature
End connection
Body material
Quantity

Typical applications

Quote for through-conduit slab gate valve

Send size, pressure class, medium and quantity. First reply within one hour, Monday to Saturday, 08:30–18:00 Beijing time.